PSF recovery with Cepstrum,
Richardson-Lucy deconvolution method.
Image-1 Loaded unsharp image
Image-2 Windowed version of Image-1 , size is extrapolated to
512*512
Image-3 Cepstrum of Image-2 , inspection reveales that the PSF is
horizontal with length 34
FFT-4 MotionBlur-form is used to make a PSF
Image-5 Richardson-Lucy deconvolution is performed on Image-2
Image-6 Windowing is removed on Image-5 , the presentation histogram
is set to L-R equalization to enhance visibility of details
|